State-of-the-art life-saving equipment on board Rega’s air-ambulances
 
Multifunktionales Überwachungsgerät
Bildschirm
Sauerstoffanlage
Spritzenpumpe/Infusionspumpe Beatmungsgerät
Spritzenpumpe/Infusionspumpe
Defibrillator, externer Herzschrittmacher
 
1. Multifunctional monitoring equipment
 
Blood pressure monitoring apparatus
Special device for measuring the blood pressure and pulse, that can be used despite aircraft noise.
Cardiovascular monitoring apparatus
The electrocardiogram of the patient is constantly monitored on the screen. If necessary, it can be connected to an external pacemaker.
Pulse oximeter/ Capnograph
The pulse oximeter measures the amount of oxygen in the blood, while the capnograph indicates how much carbon dioxide is exhaled from the lungs. Thus the doctor can determine the quality of the ventilation and increase or reduce the amount of oxygen accordingly. Around half of all patients repatriated by Rega require additional oxygen.
 
2. Respirator
Patients in a coma need to be ventilated mechanically. However, patients with abnormal breathing also need to be given oxygen-enriched air. The apparatus adapts itself to the patient’s respiratory rhythm and supports the patient's breathing.
 
3. Oxygen enrichment apparatus
Over 15,000 litres of oxygen are carried on board every flight, 3,000 of which are stored in transportable oxygen cylinders. Most of it is administered to the patient via the aircraft’s own ventilation machine. The amount of oxygen is monitored centrally.
 
4. Syringe pump/ Infusion pump
Intensive-care patients can be administered minimal doses of drugs throughout the flight with the aid of a syringe pump or an infusion pump. The pump dispenses between 0.1 ml und 999 ml per hour in highly precise doses.
 
5. Defibrillator/ External pacemaker
In the event of a patient suffering a cardiac arrest, a controlled electric shock needs to be administered to the heart. The purpose of this electric shock is to make the heart beat regularly again. If the heart is beating too slowly, the physician can make it beat faster and more regularly by applying smaller electric shocks through the skin.
 
6. Monitor
A large monitor displays the current flight route and flight/safety data, as well as the curves and readings of the various medical equipment.
 
7. Suction pump
Mucus and saliva need to be regularly sucked out of the mouths of mechanically ventilated patients to prevent them from suffocating.
 